48 hp diesel water pump

Flooded diesel pump fuel cleanup

Floodwater gets into the pump's fuel tank, and the diesel water pump will not run.

  • 3 h
  • Intermediate
  • 8 steps
  • 12 tools
Fuel system on a 48 hp diesel water pump

The whole job 8 steps

Made by AI. A mechanic hasn't checked it line by line yet. Use it to plan the job, and follow the maker's manual for specs and procedures.

Safety first

Mechanic job

Do these before step 1.

  • DANGERIsolation: lock out battery power and block the skid against movement.
  • WARNINGFlood damage: do not crank until water ingestion is ruled out.
  • WARNINGFuel: contain spills; keep ignition sources away.

Stop and call a pro or the dealer if

  • Call the dealer for suspected hydrolock, water in injection equipment or flood-damaged electrics.
  • Stop for structural damage or unseen drain and fuel-system layouts that cannot be safely verified.

Mechy's guides help, but they don't replace the maker's manual, your training or your site's rules. If something doesn't match what you see, stop and check.

Tools

Tick what you have. In the app, Mechy ticks the ones it can see in your photos.

Parts and supplies

  • 1×Fresh diesel fuelOEM-approved grade; quantity and filling limit per OEM manualCheck before you buy
  • 1×Fuel filter service setMatch installed filters and water separator; include service sealsCheck before you buy

Steps

  1. Step 1 of 8

    Lock out pump

    Stop engine, remove key, isolate battery, tag controls and block skid on firm ground.

    Crib anything raised; never work beneath a jack-supported pump.

    Lockout kit, Rated blocking

  2. Step 2 of 8

    Check flood damage

    Check intake, cylinders, oils and electrics for water before authorizing any cranking.

    Dealer procedure must clear possible hydrolock before starting.

    Inspection light, Hand tools

  3. Step 3 of 8

    Drain contaminated fuel

    Close supply, vent tank and drain its lowest point into approved waste containment.

    Use a transfer pump if no safe drain exists; never drill the tank.

    Drain container / catch pan, Approved waste fuel container, Hand tools

  4. Step 4 of 8

    Clean tank and supply

    Clean tank and low-pressure lines; flush with clean diesel until samples show no water.

    Do not push contamination into injection equipment.

    Fuel transfer pump, Clean sampling jar, Absorbent pads, Hand tools

  5. Step 5 of 8

    Service fuel filters

    Clean separator bowl and replace affected filters and seals using the OEM procedure.

    Water beyond filtration requires injection-system assessment.

    Filter wrench, Hand tools

  6. Step 6 of 8

    Close and secure

    Close drain and refit all opened fittings; check hoses, cap seal and tank vent.

    Hand tools

  7. Step 7 of 8

    Refill and prime

    Add fresh diesel, open supply and prime through designated low-pressure bleed points.

    Follow OEM bleeding instructions; never loosen high-pressure lines.

    Clean funnel, Hand tools, Clean sampling jar

  8. Step 8 of 8

    Controlled test start

    After clearance, remove lockout, prime pump casing per OEM, then test for leaks and run.

    Secure suction and discharge; stop for leaks, knock or renewed water.