Kubota · Engine
Kubota code E9006: DPF regeneration blocked by inhibit switch
Shown as E:9006. Also typed E 9006.
What it means
Kubota code E9006, shown as E:9006 on SVL track loaders and SSV skid steers, means the DPF needs a regeneration but the inhibit switch is on, so it can't start. Kubota's SVL65-2 table lists no power limit with it. Move away from people and anything flammable, press the switch to turn auto regen back on, and let the regen run.
Get the step-by-step fix in Mechy. Snap the display and the machine, say what it's doing, and Mechy turns this code into checks and repair steps for your machine. First guide free, no sign-up.
Fix E9006 in MechyCan I keep running?
Keep going carefully, fix soonUsually, if the machine runs normally: finish the job carefully and fix it soon. Stop if the machine derates, overheats, loses power or the code comes with an alarm.
Check first
- Move the machine to a safe spot away from people, animals, buildings and anything flammable. The exhaust and the DPF muffler get very hot during a regen.
- Press the regeneration inhibit switch to turn auto regen back on.
- Run the engine above 1,200 rpm once it has warmed up. If the DPF regeneration indicator blinks and the rev-up indicator lights, raise the rpm until the rev-up indicator goes out.
- Stay with the machine until the regen finishes, usually 15 to 20 minutes. Kubota says not to leave it during a regen or stop one without need.
- If the code still shows, call your Kubota dealer.
Likely causes
- Auto regen left off at the switch, for example after work near people, animals or flammable material
The fix
Turning auto regen back on lets the regeneration run, and the code should clear. Use the switch only when you need to, such as near people or anything flammable, and let a regen run soon after.
Which Kubota machines show E:9006?
SVL track loaders and SSV skid steers show it. Kubota's SVL65-2, SVL75 and SVL97-2 manuals and its SSV65/SSV75 manual all print the same meaning and the same first step for this code, and so does the SVL90 table we cite.
The steps here fit one of those machines with the code on the panel and the engine still running. A Kubota tractor shows P-codes and codes like E-93 instead. A filter Kubota says to replace is E:9004, and that's a dealer job.
How is E9006 different from E9007, E9000 and E9010?
E:9006 only asks you to turn auto regen back on, and Kubota's table lists no limit on the engine. The codes around it change the cause, add a power limit or an engine stop, or send you straight to the dealer.
| Code | What Kubota's table says | What the engine does | What to do |
|---|---|---|---|
| E:9006 | Regen needed, inhibit switch on | No limit listed | Move somewhere safe, release the switch |
| E:9007 | Same as E:9006 | Power limited. Left with the hydraulics locked, it can stop by itself | Restart, move somewhere safe, release the switch |
| E:9000 | Regen needed, engine rpm too low | No limit listed | Rev up the engine so the regen starts |
| E:9001 | Same as E:9000 | Power limited. Left with the hydraulics locked, it can stop by itself | Rev up the engine so the regen starts |
| E:9003 | Regen needed and can't start, no reason given | Power limited | Call your dealer right away |
| E:9004 | The DPF must be replaced | Power limited | Call your dealer right away |
| E:9010 | Engine stop for the DPF | The engine stops itself | Restart, move somewhere safe, release the switch |
If the code still shows after that, Kubota's answer for each one is the same: call your dealer. If the regen starts but never finishes, see why a skid steer regen won't finish, with the other causes and when the DPF needs cleaning.
What does the inhibit switch do?
The switch turns off automatic DPF regeneration. Kubota's manual says to use it when working around people, animals, plants or flammable material, and to switch it on during a regen if the heat is raising the temperature around the machine too much. One press turns auto regen off; the next press turns it back on. On the SVL65-2 it's item 8 under Switches, on page 39. Your own operator's manual shows where it sits on your machine.
With auto regen back on, the regen starts by itself once coolant, DPF and engine speed are all above Kubota's limits. All three SVL manuals we compared give the same limits.
| Regen spec | Kubota's figure |
|---|---|
| Coolant temperature | Above 65°C (149°F) |
| DPF temperature | Above 250°C (482°F) |
| Engine speed | Above 1,200 rpm |
| Usual time to finish | 15 to 20 minutes |
How long it takes depends on the outside air, the exhaust temperature and how much soot is in the filter. Keep the DPF muffler clear of anything that burns, and don't idle for long: the lower the rpm, the cooler the exhaust and the harder it is to burn the soot off.
Regen light on a Kubota tractor instead? See how to regen a Kubota tractor: the lights, the inhibit switch and a parked regen.
Different code on your screen? Find it in all Kubota codes, or snap the display and Mechy reads it.
Part broke or came off? Snap it and Mechy tells you what it is, what it's called at the parts counter and how to fit a new one.
Questions
What does Kubota code E9006 mean?
DPF regeneration blocked by inhibit switch. Kubota code E9006, shown as E:9006 on SVL track loaders and SSV skid steers, means the DPF needs a regeneration but the inhibit switch is on, so it can't start. Kubota's SVL65-2 table lists no power limit with it. Move away from people and anything flammable, press the switch to turn auto regen back on, and let the regen run.
Can I keep running with E9006?
Usually, if the machine runs normally: finish the job carefully and fix it soon. Stop if the machine derates, overheats, loses power or the code comes with an alarm.
How do I fix Kubota code E9006?
Turning auto regen back on lets the regeneration run, and the code should clear. Use the switch only when you need to, such as near people or anything flammable, and let a regen run soon after.
What's the difference between Kubota codes E9000 and E9006?
Both mean the DPF needs regenerating and regeneration can't start. With E:9000 the engine rpm is too low, so raise the rpm. With E:9006 the regeneration inhibit switch is on, so move the machine to a safe place and release the switch.
Is E9007 the same as E9006?
Nearly. Both mean a needed regeneration is blocked at the switch. Kubota's table adds for E:9007 that the engine can stop by itself if the machine is left with the hydraulics locked: restart it, move to a safe place and release the switch. If either code stays on, call your Kubota dealer.
Does this code put the machine in limp mode?
Not by Kubota's table: the SVL65-2 manual lists no power limit with E:9006. If the machine has lost power or shows E:9007, the same switch is blocking the regen and power is limited, so restart it if it stopped, move somewhere safe and release the switch.
Does E9006 mean the DPF is clogged or bad?
No. Kubota's table gives this code when a regen is due and the switch is blocking it. Replacing the filter has its own code, E:9004, and a regen that can't start for no stated reason is E:9003. On the SVL65-2 both of those limit power and go to the dealer. It isn't a CAN communication fault either, which has codes of its own such as E:001. Let the regen run before you pay for cleaning or a new filter.
How do I reset Kubota code E9006?
Press the switch to turn auto regen back on, then let the regen run. That's the only correction Kubota lists, and the SVL65-2 operator's manual gives no separate reset or clear procedure for it. A restart isn't the listed fix either: the manual says auto regen is the default when the engine starts, but for this code it still points you to the switch. If the code still shows, call your dealer.
Sources
- Kubota SVL65-2 Operator's Manual V0216-5811-3, inhibit switch p. 39, DPF regeneration pp. 46-47, E:9006 p. 119 (Kubota)
- Kubota SVL97-2 Operator's Manual, DPF regeneration and list of error code numbers (Kubota)
- Kubota SVL75 Operator's Manual, DPF regeneration and list of error code numbers (Kubota)
- Kubota SSV65 and SSV75 Operator's Manual, list of error code numbers (ManualsLib copy)
- PDF Manual 4 Trucks, Kubota SVL90 error (fault) codes list (operator's manual table)
- CodeReady, Kubota skid steer loader error codes (SVL/SSV operator's manual table)
Code meanings vary by model, serial range and software. Confirm with your operator's manual or Kubota dealer before replacing parts.
Updated · By Mechy (Winding AI, Inc.) · How we write these pages
Snap the display and Mechy reads the code
Take a photo of the screen and the machine, say what it is doing, and get the checks and the fix as steps with moving drawings.
First guide free. No sign-up, no card.